Opening the wall between the kitchen and the dining or living room is one of the most common changes homeowners ask for. In Houzz's 2026 kitchen study, a survey of its users, 52% of renovating homeowners modify their kitchen's layout, and among those who enlarge the kitchen, the dining room is the most common source of space.
If the wall in the way is load bearing, the project is usually still possible. It just becomes a structural job, with temporary supports, an engineered beam, a permit and a plan for everything that runs through the wall. Here is what each piece involves.
- Clues can suggest a wall is load bearing, but only someone tracing the framing above and below it can confirm it.
- Removal means temporary shoring, a beam sized by an engineer and posts that carry the load down to the foundation.
- A flush beam hides in the ceiling and costs more. A dropped beam hangs below it and costs less.
- Ductwork, plumbing vents and drains, wiring and gas lines inside the wall all need new routes.
- Expect a building permit and engineered drawings, and confirm the rules with your local building department.
How to tell if a wall is load bearing
A load-bearing wall carries weight from above (joists, roof framing, or a post or beam resting on it) and passes it to the structure below. A partition wall only divides space. From inside a finished room the two look identical, so the answers are above and below the wall.
The usual clues:
- It is an exterior wall. As HomeAdvisor's cost guide puts it, exterior walls always carry weight.
- It runs perpendicular to the joists above it, especially near the middle of the house, where joists often overlap or splice.
- Something sits directly below it: a beam, a wall or a row of posts in the basement.
- Something sits directly above it: a wall on the next floor, a post in the attic, or the roof ridge in a one-story house.
- It is brick. In an older city house, treat a masonry interior wall as structural until someone proves otherwise.
Clues are not proof. A wall that runs parallel to the joists can still carry a post load from above, and some roof trusses bear on an interior wall even though many span from one exterior wall to the other. Earlier remodels can also shift loads onto walls that were never meant to carry them.
That is why confirmation takes someone who traces the load from the roof down to the foundation, usually a structural engineer working with your builder. Until then, treat the wall as structural.
What removing a bearing wall involves
Taking out a bearing wall is a sequence, and each step keeps the house from moving while the load changes hands.
Temporary shoring
Before the wall comes out, the crew builds temporary stud walls or sets adjustable steel shores under the joists, usually on both sides of the wall. The shoring needs solid bearing of its own, so in a house with a basement it may continue below the floor. It stays until the new beam and posts are in and fastened.
A beam sized by an engineer
The wall's job moves to a beam. Its size depends on the span, the load above and how much it is allowed to bend, which is an engineering calculation rather than a rule of thumb. The biggest design decision is where the beam sits.
| Question | Flush beam | Dropped beam |
|---|---|---|
| Where it goes | Up in the ceiling, level with the joists | Below the joists, which rest on top of it |
| What you see | A flat, uninterrupted ceiling | A beam or soffit across the opening |
| How joists connect | Cut and hung from the beam on metal hangers | Bear on the beam as they did on the wall |
| Ceiling work | Opened along the beam to cut and hang joists | Mostly limited to the old wall line |
| Relative cost | Higher | Lower |
In a one-story house with an attic, there is sometimes a third option: set the beam in the attic above the ceiling joists and hang the joists from it. You get a flat ceiling with less cutting below, if the roof framing and attic space allow it.
LVL or steel
Most residential beams are laminated veneer lumber (LVL), an engineered wood product installed as several plies fastened together, each one manageable by hand. Steel carries more load in less depth, which helps on long spans or when a flush beam has to fit a shallow ceiling, but it is heavier and needs wood fastened to it so the joists can attach. The engineer picks the material based on the span, the load and how deep a beam you can accept.
Posts, point loads and the foundation
A beam collects the load a wall used to spread along its length and delivers it to a post at each end. That point load has to keep traveling, without a gap, through the floor framing below. The International Residential Code calls this a complete load path, one that carries loads through the structure "to the foundation."
In practice, that can mean solid blocking in the floor under each post, plus a new post and a concrete footing in the basement, because a typical basement slab is not designed for a concentrated load. Skip this step and a correctly sized beam can still leave you with cracked drywall and a dip in the floor.

What else lives in the wall
Walls between kitchens and living spaces are rarely empty. Angi's cost guide lists electrical wires, plumbing, gas lines and HVAC ducts as things that may need rerouting, each by its own trade.
- Ductwork can sometimes move into the floor or ceiling framing, or into a short chase at the end of the opening. Sometimes the only path is a soffit.
- Plumbing vents and drains usually serve fixtures elsewhere, so they cannot simply be capped. A vent has to be rerouted to code, sometimes up through a ceiling or the roof, and drains need a continuous slope.
- Wiring for switches, outlets and any circuits passing through has to move. In an older house, it often makes sense to replace old wiring rather than extend it.
- Gas lines have to be rerouted by a qualified professional.
The cheapest surprise is the one you find before demolition, through small inspection openings and a look from the basement and attic. EPA lists textured paint and patching compounds on walls and ceilings among the materials that may contain asbestos, and suggests an inspection by a trained, accredited professional before a remodel disturbs them. In a home built before 1978, ask how painted surfaces will be handled; our lead-safe renovation guide explains the federal rules.
Brick bearing walls in older St. Louis homes
St. Louis is a brick city. The City's preservation plan calls "the preponderance of brick structures in St. Louis" the legacy of the 1849 fire, and about 58% of the city's housing units were built before 1940, according to Census Bureau estimates for 2020 to 2024. In some of those houses, interior walls are solid brick too, with floor joists set into the masonry.
Opening a masonry bearing wall is a different job:
- Temporary support goes through the wall. Crews often pass steel or timber needles through the brick above the opening and shore them on both sides.
- The new beam is often steel, with solid bearing at each end: sound brick, a new masonry pier or a post with its own footing.
- Old mortar is often soft. The National Park Service notes that traditional mortar was lime and sand, and that portland cement was not in common use until the early 20th century. Cuts have to be controlled so the surrounding brick stays tight.
A wide cased or arched opening is sometimes a better answer than removing the whole wall: it opens the sight lines, keeps some of the house's character and usually costs less. New openings in masonry need engineering, which is part of Modern Design + Build's design services. Our guide to St. Louis brick homes covers the material in more depth.
Permits and engineering in the St. Louis area
Structural work generally requires a building permit and engineered drawings in St. Louis area jurisdictions. Who issues the permit, and what they want to see, depends on where you live.
- City of St. Louis. The Building Division requires a permit for "any work which involves the installation, removal or cutting of any structural beams, joist replacement or bearing support," and for removing any partition in a habitable space. Plumbing, mechanical and electrical work need separate permits when they are part of the job.
- Cities with their own building departments. Webster Groves requires a permit for "cutting, removing, or altering any structural beam or load-bearing support." Town and Country asks for plans with the seal and signature of a Missouri registered architect or engineer.
- Elsewhere. Unincorporated St. Louis County, St. Charles County, Jefferson County and many other cities set their own submittal rules and fees.
The City has adopted the 2018 International Residential Code, and that model code lets a building official require drawings prepared by a registered design professional where special conditions exist. For a bearing wall, expect the plan reviewer to want the beam size, the post locations and the path to the foundation, and expect the work to be inspected.
Rules and fees change, so confirm them with your local building department before you set a schedule. Our guide to St. Louis remodeling permits explains who issues permits where.
What drives the cost
Every bearing wall is priced on its own conditions. The main drivers:
- Span and load. A longer opening, or a wall holding up a floor and a roof, needs a bigger beam and sometimes steel.
- Flush or dropped. Hiding the beam in the ceiling means cutting joists, hanging them and more ceiling repair.
- Posts and footings. New footings in a basement or crawlspace add digging, concrete and time.
- What is inside the wall. Each rerouted duct, vent, drain, circuit or gas line adds a trade.
- Finish work. The floor where the wall stood needs patching or replacing, the ceiling and walls need repair, and trim and paint have to tie two rooms together.
- Older materials and brick. Asbestos testing, lead-safe work practices and masonry all add labor.
National cost guides give a sense of scale for the structural part of the job:
| Item | National figure | Source |
|---|---|---|
| Removing a load-bearing wall | $500 to $15,000; most spend around $3,000 | HomeAdvisor, updated June 2026 |
| Removing a load-bearing wall, average | $5,700 | Angi, updated July 2026 |
| Single-story home | $1,200 to $3,000 | HomeAdvisor, updated June 2026 |
| Multi-story home | $3,200 to $10,000 | HomeAdvisor, updated June 2026 |
| Structural engineer | $350 to $800 | HomeAdvisor, updated June 2026 |
Treat these as national figures for the wall itself, not a St. Louis price for a finished room. Both guides say to budget separately for rerouting plumbing and wiring, and HomeAdvisor adds drywall, painting and possible mold or asbestos remediation. A flush beam with new footings, a moved duct and new flooring across two rooms will land well above the low end, so plan around a number tied to a design and a written scope.

If you are planning to open up a kitchen, start with two questions: what is the wall carrying, and what is inside it? At Modern Design + Build, engineering is part of our design services, so the beam, the posts and the drawings are worked out as part of the project, before anything comes down. See our kitchen remodeling and whole-home renovation services, or book a free consultation to talk it through.
- 2026 U.S. Houzz Kitchen Trends Study, Houzz
- How Much Does It Cost to Remove a Load-Bearing Wall in 2026? (updated June 20, 2026), HomeAdvisor
- How Much Does It Cost to Remove a Load-Bearing Wall? (updated July 15, 2026), Angi
- 2018 International Residential Code, Chapter 3, Section R301.1, International Code Council
- 2018 International Residential Code, Chapter 1, Section R106.1, International Code Council
- Building Codes Adopted by the City, City of St. Louis
- When a Residential Building Permit is Needed, City of St. Louis
- Building Permits, City of Webster Groves
- Building Permits and Inspections, City of Town and Country
- Learn About Asbestos, U.S. EPA
- Protect Your Family from Exposures to Asbestos, U.S. EPA
- Preservation Plan, Part I: Community Planning, City of St. Louis
- Year Structure Built (Table B25034), ACS 2024 5-year estimates, U.S. Census Bureau via Census Reporter
- Preservation Brief 2: Repointing Mortar Joints in Historic Masonry Buildings, National Park Service


